Check Whether Your Bin Fan Delivers Enough Airflow

16 November 2026
Conceptual illustration of deeper and shallower columns of shelled corn, emphasizing grain depth when checking bin airflow.

Check the fan at the fill depth you use

You can check whether your existing bin fan fits the job by estimating airflow per bushel at the actual grain depth. Use a fan calculator, or match measured operating pressure to your exact fan model’s performance data. Then compare the result with cooling or natural-air-drying needs—not motor horsepower alone.

Start with the job, not the motor

Two fans with the same horsepower can deliver different airflow. As the pressure a fan works against rises, its airflow falls. Crop type and grain depth affect that resistance, so a fan rating by itself does not describe airflow through your grain.

University of Minnesota Extension gives these airflow ranges for grains and oilseeds:
– Stored-grain aeration: 0.05–0.5 cubic feet per minute per bushel, written as cfm/bu.
– Natural-air drying: 0.75–1.5 cfm/bu.

A setup that supplies aeration airflow may fall short for natural-air drying. These are job-specific airflow ranges; a natural-air-drying decision also needs guidance suited to the crop’s moisture and weather conditions.

Use a calculator for an initial estimate

Gather the crop, exact fan make and model, bin dimensions, floor arrangement and actual grain depth. In the University of Minnesota fan-selection calculator, select the stored crop and installed fan, enter the bin parameters, and find the estimated cfm/bu at that depth.

Iowa State Extension’s October 28, 2021 guidance shows why depth matters. Its calculator example uses shelled corn in a 21-foot-diameter bin with a full floor and a 2-hp Brock 18-inch axial fan:
– At 20 feet of grain depth: 0.55 cfm/bu.
– At 12 feet of grain depth: 1.07 cfm/bu.

The deeper fill falls below Minnesota’s natural-air-drying range; the shallower fill falls within it. Those are calculator estimates for that specific setup, not measurements or ratings for every 2-hp fan. The useful lesson is to check the depth you actually have—not simply the bin’s maximum capacity.

Use operating pressure to check the installed setup

A pressure-based estimate uses a reading from the running system rather than relying only on entered bin conditions. Static pressure is the pressure the fan works against, expressed in inches of water.

Minnesota Extension describes this method:
1. Measure pressure in the duct or plenum—the air chamber—between the fan and the grain. Use a pressure gauge or U-tube manometer connected at a small opening in the duct or plenum wall.
2. Take the reading with the fan operating. A U-tube manometer leaves one end open to the atmosphere; the difference between its two water levels gives the pressure in inches of water.
3. Use the reading’s magnitude, treating a negative reading as positive, to look up total airflow in the exact fan model’s performance table or curve.
4. Divide that total airflow by the bushels served by the fan.

Ask the manufacturer for performance data based on Air Movement and Control Association International, or AMCA, testing. Do not substitute another model’s curve because its horsepower matches.

Airflow per bushel = total airflow in cfm ÷ bushels served.

For an arithmetic example only, assume the matching fan table gives 6,000 cfm at the measured pressure and the fan serves 10,000 bushels. The estimate is 6,000 ÷ 10,000 = 0.60 cfm/bu, below Minnesota’s 0.75 cfm/bu lower end for natural-air drying.

This is an airflow estimate based on measured pressure and model data—not a direct airflow measurement.

Use the result to choose the next step

If airflow falls short for the intended job, discuss a shallower fill or a fan change with your bin supplier or an Extension agricultural engineer. Nebraska Extension’s November 20, 2009 drying guidance recommends partial fills when higher airflow rates are needed. Recalculate or repeat the pressure-based check at the proposed depth before relying on it.

Keep the fan model, crop, grain depth, bushels served, floor arrangement, pressure reading and resulting cfm/bu together. Those records give the person helping you a specific setup to evaluate.

Repeat the pressure-based check when the crop, depth, amount of fines or way the grain is piled changes. An earlier airflow estimate describes the earlier bin conditions—not every load that fan will handle.